Vertical contact toaster, Troubleshooting – A.J. Antunes & Co VCT-2000 9210214 User Manual

Page 15

Advertising
background image

15

VERTICAL CONTACT TOASTER

P/N 1010874 Rev. I 04/14

TROUBLESHOOTING

WARNING

To avoid possible personal injury and/or damage to the unit, inspection, test and repair of electrical equip-

ment should be performed by qualified service personnel. The unit should be unplugged when servicing,

except when electrical tests are required. Use extreme care during electrical circuit tests. Live circuits will

be exposed.

Problem

Possible Cause

Corrective Action

Control Display flashes

LO” continuously.

Buns not toasting

properly.

Platen temperature is below 440ºF

(226ºC).

Allow the unit to warm up for 30 minutes and then

recheck. If the Control Display still reads “

LO”,

contact your maintenance person or Authorized

Service Agency for service.

Control display flashes

LO” continuously.

Buns Burn.

Failed Platen Thermocouple.

Contact your maintenance person or Authorized

Service Agency for service.

Failed Control Board.

Control Display

flashes “

PO” continu-

ously.

The power to the unit is below 190

volts.

Turn the power off and then back on. If the display

still shows “

PO”, check the power cord, plug, and

outlet for damage.

Reset the Circuit Breakers.

Contact your maintenance person, Authorized

Service Agency, or electrician for service.

Failed Control Board.
Failed Transformer.

Control flashes

CHEC” continuously.

Control Compartment temperature is

above 140ºF (60°C).

Verify side vents on toaster are unblocked and not

near other heating appliances. If problem still

persists, contact your maintenance person or

Authorized Service Agency for service.

Failed Cooling Fan.
Failed Control Board.

Control Display

flashes “

HI” continu-

ously.

Buns burn.

Failed Platen Solid State Relay.

Contact your maintenance person or Authorized

Service Agency for service.

Failed Control Board.
Failed Platen Thermocouple.

Control Display flash-

es “

HI” continuously.

Buns not toasting

properly.

Loose Platen Thermocouple connec-

tion on Control Board or the Platen

Thermocouple is open.

Re-secure the Platen Thermocouple connection to

the Control Board. If the Control Display still reads

HI”, check the Thermocouple for continuity.

Contact your maintenance person or Authorized

Service Agency for service.

Failed Control Board.

Control Display

flashes “

HI” and “LO

at cold start up, then

HI” and “USE” after

20–30 minutes.

Loose Auxiliary Thermocouple

connection on Control Board or

Thermocouple is open.

Re-secure the Auxiliary Thermocouple connection to

the Control Board. If the Control Display still reads

HI” and “LO” or “HI” and “USE”, check Thermocou-

ple for continuity. Contact your maintenance person

or Authorized Service Agency for service.

No Control Display.

Unit not plugged in.

Plug unit into the proper electrical outlet.

Hi-Limit control has tripped.

Allow unit to cool and reset the Hi-Limit control. If

it trips again, contact your maintenance person or

Authorized Service Agency.

Circuit Breakers turned off or tripped.

Damaged electrical outlet, plug, or

cord. Power Switch damaged.

Reset Circuit Breakers. If they trip again, check the

cord, plug, and outlet for damage.

Contact your maintenance person, Authorized

Service Agency, or electrician.