Vertical contact toaster, Sp - p 600, 400 sp - a – A.J. Antunes & Co VCT-2000 9210214 User Manual
Page 9: Lo use, Operation (continued)
9
VERTICAL CONTACT TOASTER
P/N 1010874 Rev. I 04/14
TEMPERATURE CONTROL PANEL
NOTE: The term “setpoint temperature” refers to
the desired temperature setting.
To display the actual Platen temperature
—providing it
is over 440°F (227°C)
—press the TEMP UP button.
To display the actual Auxiliary Air Heater temperature
—
providing it is over 360°F (182°C)
—press the TEMP
DOWN button.
To switch the temperature display between Fahrenheit
(°F) and Celsius (°C), press and hold the
TEMP
SCALE button for 5 seconds.
PLATEN HEATER TEMPERATURE ADJUSTMENT
1. Turn the power on and wait for the Temperature
Display to finish the power-up sequence (Figure 4).
2. Press and hold the
TEMP UP and TEMP DOWN
buttons for more than 1 second until the display
flashes the Platen setpoint temperature, then
release.
3. Press the
TEMP UP button to raise the setpoint
temperature or press the
TEMP DOWN button to
lower the setpoint temperature.
NOTE: The maximum Platen setpoint temperature
is 600°F (315°C). If no change in temperature is
made within 5 seconds, the display reverts back to
the previous setpoint.
4. Release the button when the desired setpoint is
displayed.
AUXILIARY AIR HEATER TEMPERATURE ADJUSTMENT
1. Turn the power on and wait for Temperature Display
to finish the power-up sequence (Figure 4).
2. Press and hold the
TEMP UP and TEMP SCALE
buttons for more than 1 second until the display
flashes the setpoint temperature, then release.
3. Press the
TEMP UP button to raise the setpoint
temperature or press the
TEMP DOWN button to
lower the setpoint temperature.
NOTE: The maximum Auxiliary Air Heater setpoint
temperature is 400°F (204°C).
4. Release the button when the desired setpoint is
displayed.
NOTE: If no change in temperature is made within
5 seconds, the display reverts back to the previous
setpoint.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
SP - P
600
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
TEMP
UP
TEMP
DOWN
TEMP
SCALE
˚F
˚C
POWER
400
SP - A
Figure 4. Temperature Power-Up Sequence
3. “
SP-A” (Setpoint Auxiliary)
is displayed.
1. “
SP-P” (Setpoint Platen)
is displayed.
“Heat On” LED will blink on/off during warm-up and when either
platen or auxiliary air heaters are calling for heat.
2. Current Platen setpoint
temperature setting is shown.
4. Current Auxiliary Air setpoint
temperature is shown.
5. “
LO” is displayed until
Platen temperature rises
above 550°F (288°C).
6. “
USE” is displayed when
Platen setpoint temperature*
is reached.
TEMP
UP
TEMP
DOWN
TEMP
SCALE
°F
°C
POWER
LO
USE
* Platen setpoint temperature
must be between 460°F and
600°F (238°C and 315°C).
OPERATION (continued)