VERTICAL CONTACT TOASTER

P/N 1010874 Rev. I 04/14

TEMPERATURE CONTROL PANEL

NOTE: The term “setpoint temperature” refers to

the desired temperature setting.
To display the actual Platen temperature

providing it

is over 440°F (227°C)

press the TEMP UP button.

To display the actual Auxiliary Air Heater temperature

providing it is over 360°F (182°C)

press the TEMP

DOWN button.
To switch the temperature display between Fahrenheit

(°F) and Celsius (°C), press and hold the

TEMP

SCALE button for 5 seconds.

PLATEN HEATER TEMPERATURE ADJUSTMENT

1. Turn the power on and wait for the Temperature

Display to finish the power-up sequence (Figure 4).

2. Press and hold the

TEMP UP and TEMP DOWN

buttons for more than 1 second until the display

flashes the Platen setpoint temperature, then

release.

3. Press the

TEMP UP button to raise the setpoint

temperature or press the

TEMP DOWN button to

lower the setpoint temperature.

NOTE: The maximum Platen setpoint temperature

is 600°F (315°C). If no change in temperature is

made within 5 seconds, the display reverts back to

the previous setpoint.
4. Release the button when the desired setpoint is

displayed.

AUXILIARY AIR HEATER TEMPERATURE ADJUSTMENT

1. Turn the power on and wait for Temperature Display

to finish the power-up sequence (Figure 4).

2. Press and hold the

TEMP UP and TEMP SCALE

buttons for more than 1 second until the display

flashes the setpoint temperature, then release.

3. Press the

TEMP UP button to raise the setpoint

temperature or press the

TEMP DOWN button to

lower the setpoint temperature.

NOTE: The maximum Auxiliary Air Heater setpoint

temperature is 400°F (204°C).
4. Release the button when the desired setpoint is

displayed.

NOTE: If no change in temperature is made within

5 seconds, the display reverts back to the previous

setpoint.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

SP - P

600

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

TEMP

UP

TEMP

DOWN

TEMP

SCALE

˚F

˚C

POWER

400

SP - A

Figure 4. Temperature Power-Up Sequence

3. “

SP-A” (Setpoint Auxiliary)

is displayed.

1. “

SP-P” (Setpoint Platen)

is displayed.

“Heat On” LED will blink on/off during warm-up and when either

platen or auxiliary air heaters are calling for heat.

2. Current Platen setpoint

temperature setting is shown.

4. Current Auxiliary Air setpoint

temperature is shown.

5. “

LO” is displayed until

Platen temperature rises

above 550°F (288°C).

6. “

USE” is displayed when

Platen setpoint temperature*

is reached.

TEMP

UP

TEMP

DOWN

TEMP

SCALE

°F

°C

POWER

LO

USE

* Platen setpoint temperature

must be between 460°F and

600°F (238°C and 315°C).

OPERATION (continued)