Installation (cont.) – AccuTemp ACCU-STEAM GAS GRIDDLE User Manual

Page 14

Advertising
background image

AT2T-3238-1 Rev. C

ACCU-STEAM GAS GRIDDLE OWNERS MANUAL

Page

9/29

INSTALLATION (cont.)

Figure 2

Adjust the regulator(s) as needed to comply with the pressures indicated on the

griddle orifice and pressure specification label. See Figure 2 for the orifice and pressure
specification data.

Figure 3

The system gas supply pressures for the main and pilot burners should be verified

with a manometer while the appliance is operating in a maximum load condition. A

1/8” NPT tap is provided in the front of the main regulator valve, to measure the main
burner supply pressure. A second ¼” NPT tap is located just to the right of the pilot
burner regulator for measurement of the pilot burner supply pressure. See Figure 3 for
the pressure tap locations. Use a pipe joint compound or sealant designed for use with

liquid petroleum gas when replacing the

1/8

” NPT plug or the ¼” NPT plug.

NOTE: Do not use an excessive amount of sealant, in order to prevent potential
obstruction of orifices and control valves.

1/8” NPT

1/4” NPT