FS 3805-0804 Page 2 of 4


PM TASK DESCRIPTIONS

DAILY

ITEMS

BI-

ANNUAL

ITEMS

ANNUAL

ITEMS

10. Inspect the burner venturi tubes for foreign particles.

Wipe out with a mild detergent and warm water and rinse
with clean water.

X

X

11. Inspect combustion chamber and the burner tiles. If

water stains are present on tiles check that tiles have no
cracks and haven’t sunk into the burner. Replace
burners if this condition is present. If when cleaning the
vent hood water and solvent drip down into the flue,
consider adding a back draft diverter. This devise keeps
foreign material out of flue and combustion chamber.
Serious consideration should be given since most
solvents used for cleaning hoods are corrosive to the
ceramic tiles.

X

X

12. Inspect the ignition wire harness for any evidence of high

temperature degradation or grease build-up on the
harness connector. Spray contact cleaner into white
connector and clean mating connector imbedded in
ignition module. Replace harness if it doesn’t have high
heat quick disconnect on end of orange wire. Install heat
shield if not already installed.

X

X

13. Verify ignition module voltage (MV) output greater than

30 MV. Must have AccuTemp adaptor ATR-FT003 to
check millivolts. Install ground strap between stand-by
burner and control panel to improve ground plane
performance.

X

X

14. Verify pilot burner and main burner regulator pressures.

Check that stand-by burner tile is flush with surface of
burner and if not replace pilot burner.

X

15. Check output of control transformer after unit has been

running for several hours. The output of the secondary
coil must be greater than 20 volts or if less than this
replace transformer.

X

X