AT2T-3238-1 Rev. C

ACCU-STEAM GAS GRIDDLE OWNERS MANUAL

Page

4/29

INSTALLATION

This installation must conform with local codes, or in the absence of local codes, with

National Fuel Gas Code, ANSA/NFPA 54

, or the

Natural Gas and Propane

Installation Code, CSA B149.1

, as applicable.

The appliance and its individual shutoff must be disconnected from the

gas supply piping system during any pressure testing of that system at test
pressures in excess of ½ psi (3.5kPa)

The appliance must be isolated from the gas supply piping system by

closing its individual manual shut off valve during any testing of the gas
supply piping system at a test pressure equal to or less than ½ psi (3.5kPa).
LOCATION AND PLACEMENT

The AccuTemp

A

CCU

-S

TEAM

gas griddle can be placed on a commercial kitchen

counter-top or AccuTemp griddle stand.

The operating temperature ranges from 200°- 400°F (93°- 204°C). Since these

temperatures can also be found on surfaces around the perimeter of the griddle, care
should be given not to install griddle next to or against, objects or surfaces with a low
melting or flash point. See Figure 1 for clearance restrictions.

Figure 1

WARNING

Only qualified service technicians/electricians should perform the

installation to ensure that all electrical and safety requirements are met

and that all wiring is performed in accordance with all national, state and

local electrical codes.

CAUTION

Temperatures on and around the griddle cooking surface could cause

severe burns.

CLEARANCE RESTRICTIONS

COMBUSTIBLE

NON-COMBUSTIBLE

SIDES

1”

0”

REAR

2”

0”