Dmx-512 control connection, Dmx-512 connection with dmx terminator – elektraLite eyeBall RGBWA (5-in-1) User Manual

Page 4

Advertising
background image










5. DMX-512 Control Connection

Connect an XLR cable to the female 5-pin XLR output of your ElektraLite CP16/24 or other DMX
controller. The other end should be connected to the male 5-pin XLR input of the ElektraLite eyeBall
(5-in-1)

. Then daisy-chain out of the first ElektraLite eyeBall (5-in-1) into the next ElektraLite eyeBall

(5-in-1)

or other dmx device. Never “Y” split the DMX connection.

If you need more cable, then it should be two core, screened cable fitted with a 5 pin XLR input and
output connector. Please refer to the diagram below.

1

2

3

4

5


DMX-512 connection with DMX terminator

For installations where the DMX cable has to run a long distance or is in an electrically “noisy”
environment, it is recommended that a DMX terminator is used. This helps prevent corruption of the
digital control signal. The DMX terminator is simply a 5 pin XLR plug (male) with a 120 Ω resistor
connected between pins 2 and 3. It is then plugged into the output XLR socket of the last ElektraLite
eyeBall

(5-in-1) or other dmx device in the chain. Please see illustration below.

1

2

3

4

5

Ω

120

Advertising