Set audio sensitivity – elektraLite CP1 User Manual

Page 16

Advertising
background image

product manual

model nº c p 1

# E_10051a

Elektralite

Use the number keyswitches to select each instrument (1-8) then use the” + “ and “-” keys to toggle between 6 channel
Gold Scan and 4 channel Mini Scan (Silverado). You must set each instrument separately. This allows the CP-1 to adjust
Its channel output internally so that the control signals will be directed properly for the instrument type.

Set Audio Sensitivity

Press “Enter”, “Scene”, “999”, “Enter”. The display will read:

AUDIO IN SENSE 5

0-LEAST, 9-MOST

Select a value from (0-9) to control the sensitivity of the audio input which is used to sync chase speed to audio. The
audio input is a line level input with a low pass filter driving trigger and debounce routines. In order to be effective the
music on this input must have some sort of pulsing beat to drive the chase.

The sensitivity sets the trigger level with 0 being the least sensitive and 9 being the most sensitive. If the audio source
can be adjusted, leave this setting at 5 and adjust at the source. If the signal can’t be adjusted, try different settings
until you get the best results. A setting of 9 would be for very weak audio signals and a setting of 0 would be for strong
signals.