Error messages – elektraLite Elektrik Eye User Manual

Page 19

Advertising
background image

-

18 -







Channel 9 – Pan 16 Bit (fine)

Channel 10 – Tilt 16 Bit (fine)


ERROR MESSAGES

When you turn on the fixture, it will reset first. The display may show “Xer” while there are problems with one or
more channels. “XX” stands for channel 1,2,3,5,& 6, which has the testing sensor for positioning .
So, for example, when the display shows “02Er”, it means there is some error in channel 2. If there are errors
on channel 1, channel 2, channel 5 at the same time, you will see the error message “01Er”, “02Er”,”05Er” flash
repeated for 5 times. Then the fixture will generate a reset signal to all the stepper motors. If the error message
remains after performing reset more than 3 times, it will detect whether the fixture has more than 3 errors.

01Er:

Color wheel error. This message will appear after resetting Elektric Eye and the magnetic-indexing circuit
malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive circuit
on the main circuit board). Normally after a reset, the color wheel will go to its default position.

02Er:

Rotating gobo wheel error. This message will appear after resetting Elektric Eye and the magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive
circuit on the main circuit board). Normally after a reset, the rotating gobo wheel will go to its default position.

03Er:

Rotating gobo indexing error. This message will appear after resetting Elektric Eye and the magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive
circuit on the main circuit board). Normally after a reset, the rotating gobo will go to its default position.

05Er:

Pan movement error. This message will appear after resetting Elektric Eye and the yoke’s magnetic-indexing
circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it could be the drive
IC on the main circuit board). Normally after a reset, the yoke will go to its default position.

06Er:

Tilt head movement error. This message will appear after resetting Elektric Eye and the head’s
magnetic-indexing circuit malfunctions (sensor failed or magnet missing) or the stepper motor is defective (or it
could be the drive IC on the main circuit board). Normally after a reset, the head will go to its default position.

Advertising