CLEANING AND MAINTENANCE

1. All bolts and safety chains must be tightly screwed into position and have no corrosion.
2. Regularly check all mechanic moving parts for wear. They must rotate freely and in no way stick or

squeak.

3. Regularly look for wear and tear on the 120 volt input cable and the DMX signal cable.
4. Clean

Elektric Eye at frequent intervals. Use a moist lint free cloth. Do not use a wet cloth or a cloth

with alcohol or solvents added. Clean lens and the reflector when the lamp is off, disconnected from
the 120 supply and when it is cool.

TECHNICAL SPECIFICATIONS

Power supply : 120VAC, 60Hz
Power consumption : max. 400 VA
Lamp : MSD250/2 GY9.5 socket, Metal Halide
Motors : 8 micro motors
Packing dimensions :58cm x 42cm x 46cm [23” x17 ” x 18”]
Net weight : 16 KGS; 35 lbs
Gross weight: 19 KGS; 42 lbs.