AXIS 223M - Unit Connectors

Unit Connectors

This section describes the following:

• The I/O Terminal connector
• Power connections
• The RS-232 D-Sub Connector

I/O Terminal connector

The 10-pin I/O terminal connector provides the interface to a solid state relay output, two

digital photo-coupled inputs, RS-485, GND and auxiliary power.

The terminal connector is used in applications for motion detection, event triggering, time

lapse recording, alarm notification via e-mail, image storage to FTP locations, and more.

Input - Used for connecting external alarm devices and triggering images for

specific alarm-based events. The input is typically connected to a motion detector

or any other external security device, and images can be uploaded whenever the

detector is activated. Maximum 18V DC is allowed on the input.

Output - This can drive a maximum load of 50VDC or 35VAC at 100mA directly

or heavier loads by connecting additional relay circuitry. If the output is used

with an external relay, a diode must be connected in parallel with the load for

protection against any voltage transients.

Caution!

Connecting AC to the inputs/outputs will damage the unit.

10-pin I/O

Terminal connector

(including RS-485)

connector

Power

block

connector

Power adapter

RS-232 connector

Connect DC power (7-24V) on pins 1 and 2.

Connect AC power (10-24V) on pins 2 and 3.

Audio out

Audio in

Reset/Control

Button

Network connector