AXIS 223M - Unit Connectors

I/O Terminal connector pinout table

I/O Terminal connector schematic diagram
Example schematic diagram of the AXIS 223M terminal connector - showing possible

applications.

Pin

Function Description

1

Output A

On the external device output terminals (A and B), there is no distinction
between positive and negative (+ and -). The terminals use a photocou-
pler and are electrically isolated from the other internal circuitry.

The maximum load should not exceed 100mA and the maximum voltage
should be not more than 50VDC or 35VAC.

2

Output B

3

Digital Input 1- Photocoupler Anode (+)

Photocoupled Input 1. Electrically isolated from the chassis and connec-
tors, this input can be supplied from an external DC voltage or the DC
Power Input/Output on pins 9 (DC+) and 10 (GND).

4

Digital Input 1 - Photocoupler Cathode (-)

5

Digital Input 2 - Photocoupler Anode (+)

Photocoupled Input 2. As above.

6

Digital Input 2 - Photocoupler Cathode (-)

7

RS-485-A (non-inverting)

A half-duplex RS-485 interface for controlling auxiliary equipment.

8

RS-485-B (inverting)

9

DC + Power Output

This can drive the photocoupler inputs or other equipment. The output
voltage level is 3.0 V. A maximum current of 100mA can be sourced from
the DC output.

10

GND

Ground.

o

o

Control

Device

o

o

o

o

A

B

3

4

5

6

7
8

External Device

Active

_

+

o

o

1

2

RS-485

Mains Power

24V DC

Appliance

Optional

Relay

Switch

o

o

o

o o

o

o

o

o

9

10

+

-

Switch, etc.