Adjusting the recording level, Recording tips, Checking the remaining recordable time on the md – Sony MDS-S40 User Manual

Page 16: Monitoring the input signal (input monitor)

Advertising
background image

16

Recor

ding on MDs

Adjusting the Recording
Level

Do the procedure below to adjust the recording level.

LEVEL/DISPLAY/CHAR

AMS

` / 1

N

z

x

X

Z

>

.

m

M

1

Do steps 1 to 10 of “Recording on an MD” on pages
14 and 15.

2

Play the portion of the program source with the
strongest output.

3

Press LEVEL/DISPLAY/CHAR (or DISPLAY) repeatedly
until the peak level meters appear.

4

While monitoring the sound, turn AMS (or press
.

/> repeatedly) to raise the recording level to

its highest level without turning on “OVER” on the
peak level meters.
Occasional lighting of “OVER” is acceptable.

Avoid turning this indication on.

5

Stop playing the program source.

6

To start recording, continue from step 12 of
“Recording on an MD” on page 15.

z

You can adjust the recording level using the remote Z

During recording or recording pause, press LEVEL +/–
repeatedly.

z

To display the level of the strongest signal

The Peak Hold function continuously displays the level of the
strongest signal that has been input.
Do the procedure below to turn Peak Hold on.
1 While the deck is stopped, press MENU/NO twice to display

“Setup Menu.”

2 Turn AMS (or press ./> repeatedly) until “P.Hold”

appears, then press AMS or YES.

3 Turn AMS (or press ./> repeatedly) to select “P.Hold

On,” then press AMS or YES.

4 Press MENU/NO.

To turn Peak Hold off, repeat the procedure above, selecting
“P.Hold Off” in step 3.

Recording Tips

LEVEL/DISPLAY/CHAR

INPUT

AMS YES

EJECT Z

MENU/NO

z

` / 1

N

z

x

X

Z

>

.

m

M

Checking the remaining recordable time
on the MD

Press LEVEL/DISPLAY/CHAR (or DISPLAY) repeatedly.

While the deck is

The following information appears

Stopped

Total number of tracks and total recorded
time t Remaining recordable time on
the MD t Disc name

Recording

Recorded time of the current track t
Remaining recordable time on the MD t
Input level indication t Track name

For details, see page 12.

Monitoring the input signal
(Input Monitor)

You can monitor the selected input signal even when
you’re not recording it.

1

Press EJECT Z to eject the MD.

2

Set INPUT to the position that corresponds to the
jacks (connector) where the signal you want to
monitor is being input.

3

Press z.

When INPUT is set to ANALOG
The analog signal input from the LINE (ANALOG) IN
jacks is output to the LINE (ANALOG) OUT jacks
after A/D and D/A conversions. “AD - DA” appears
in the display at this time.

When INPUT is set to DIGITAL
The digital signal input from the DIGITAL IN
connector first passes through the sampling rate
converter, and then output to the LINE (ANALOG)
OUT jacks after D/A conversion. “- DA” appears in
the display at this time.

To stop monitoring the signal
Press x.

Advertising