Measuring dc voltage, Measuring resistance, Fig. 7 – Actron Digital Multimeter CP7676 User Manual

Page 8: Fig. 8

Advertising
background image

2K 200

20M

2M

200K

20K

OHMS

750V AC
200V DC

COM

V

DWELL

4

CYL

5

CYL

6

CYL

8

CYL

4

CYL

5

CYL

6

CYL

8

CYL

2K 200

200

750

20

2

20M

2M

200K

20K

DC V

AC V

OHMS

®

CP7676

RPM

X10

750V AC
200V DC

COM

V

DWELL

4

CYL

5

CYL

6

CYL

8

CYL

OFF

8

Measuring DC Voltage

This multimeter can be used to measure DC

voltages in the range from 0 to 200V. You

can use this multimeter to do any DC voltage

measurement called out in the vehicle

service manual. The most common

applications are measuring voltage drops,

and checking if the correct voltage arrived at

a sensor or a particular circuit.

6. View reading on display - Note range

setting for correct units.

NOTE: 200mV = 0.2V

Measuring Resistance

Resistance is measured in electrical units

called ohms (

). The digital multimeter can

measure resistance from 0.1

to 20M

or

(20,000,000 ohms). Infinite resistance is

shown with a “1” on the left side of display

(See Setting the Range on page 6). You can

use this multimeter to do any resistance

measurement called out in the vehicle

service manual. Testing ignition coils, spark

plug wires, and some engine sensors are

common uses for the OHMS (

) function.

To measure Resistance (see Fig. 8):

To measure DC Voltages (see Fig. 7):

1. Insert BLACK test lead into the COM

test lead jack.

2. Insert RED test lead into the test lead

jack.

3. Connect RED test lead to positive (+)

side of voltage source.

4. Connect BLACK test lead to negative

(-) side of voltage source.

NOTE: If you don’t know which side is

positive (+) and which side is negative (-),

then arbitrarily connect the RED test lead

to one side and the BLACK to the other.

The multimeter automatically senses

polarity and will display a minus (-) sign

when negative polarity is measured. If you

switch the RED and BLACK test leads,

positive polarity will now be indicated on

the display. Measuring negative voltages

causes no harm to the multimeter.

5. Turn multimeter rotary switch to

desired voltage range.

If the approximate voltage is unknown, start

at the largest voltage range and decrease

to the appropriate range as required. (See

Setting the Range on page 6)

1. Turn circuit power OFF.

To get an accurate resistance

measurement and avoid possible damage

to the digital multimeter and electrical

circuit under test, turn off all electrical

power in the circuit where the resistance

measurement is being taken.

2. Insert BLACK test lead into the COM

test lead jack.

3. Insert RED test lead into the

V

test

lead jack.

4. Turn multimeter rotary switch to 200

range.

Touch RED and BLACK multimeter leads

together and view reading on display.

Display should read typically 0.2

to 1.5

.

If display reading was greater than 1.5

,

check both ends of test leads for bad

connections. If bad connections are

found, replace test leads.

Black

Fig. 7

Red

Black

Fig. 8

Unknown

Resistance

Red

Advertising
This manual is related to the following products: