Maintenance

F232060

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

See Figure 14. Loosen motor mounting
bolts and slide motor along motor plate
to change belt span length. Belt
deflection should be measured as close
to the center of the span length as
possible. A set force should be applied
in the center of the span length, as
specified in the table below.

Figure 14

c. Verify that the V-belt is properly

aligned by checking pulley alignment.
Place a straightedge across both pulley
faces. The straightedge should make
contact with the pulleys in four places.
See Figure 15.

Figure 15

3. Remove back panel and check overflow

hose and drain hose for leaks.

4. Unlock the hinged lid and check the

supply dispenser hoses and hose
connections.

5. Clean inlet hose filter screen:

a. Turn water off and allow valve to

cool, if necessary.

b. Unscrew inlet hose and remove

filter screen.

c. Clean with soapy water and reinstall.

Replace if worn or damaged.

6. Tighten motor mounting bolt locknuts and

bearing bolt locknuts, if necessary.

7. Use compressed air to clean lint from

motor.

8. Clean interior of machine, both

basket and shell, by wiping with
a water-soaked sponge or cloth.

9. Use compressed air to ensure that all

electrical components are free of
moisture and dust.

Machine

Capacity

(lbs)

Deflection

(in)

Force Applied

(lbs)

18

0.246

5.6

25

0.250

5.6

GV001IE1A

Deflection

Span

Length

GV002BE1A

Motor

Drive Pulley

Driven

Pulley

Straightedge