Removal from service – Alliance Laundry Systems SF18VNV User Manual

Page 45

Advertising
background image

F232060

43

Section 4

Removal from Service

© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT

Decommissioning

In the event that the machine must be
decommissioned, follow these steps:

1. Remove the chemical injection supply

system, if applicable.

a. Have a qualified electrician

disconnect power to the chemical
injection supply system at
its source.

b. Using the manufacturer’s

instructions, carefully remove the
chemical injection supply system from
the machine. Make certain that no
chemical supplies come into contact
with skin or clothing.

2. Clean interior of machine, both

basket and shell.

a. Flush supply dispenser (soap dish)

with water.

b. Run a short rinse cycle to clean

detergent and chemical residues from
the interior of the machine.

3. Disconnect electrical power.

a. Shut off main power supply at the

breaker box or main control panel.

b. Do not attempt to disconnect power

supply wires from power supply. Have
a qualified electrician disconnect power
to machine at its source.

4. Disconnect hoses.

a. Disconnect drain hose from sump,

gutter, or drain.

b. Turn off water supply. Disconnect

individual hot and cold water inlet
hoses from the machine.

c. Allow time for residual water in the

machine to drain. Then disconnect
drain hose from the machine.

5. Disconnect steam hose, if applicable.

a. Turn off steam supply and allow

time for the valve to cool.

b. Disconnect steam hose

from machine.

6. Remove the machine from its

foundation pad.

a. Keep all panels in place to

provide stability when moving
the machine.

b. Verify that door is closed

and secure.

c. Loosen and remove anchor bolts

holding machine base to floor, if
applicable.

d. Break the grout seal at each corner of

the machine, using a crowbar.

Advertising
This manual is related to the following products: