cdma2000 System
6
N9360A Multi UE Tester Quick Reference Guide
6-7
For Pinpointing Failures
Figure 6-5 [Auto Test (1xEV-DO): Stand-by] Screen
1
Perform the steps described in "For Go/No-Go" Testing".
2
Press the Screen>> softkey to set screen mode to Value.
3
Check the values of the measurement results.
Table 6-2 1xEVDO Automatic Test Sequence
Step
Action Needed
UATI Assignment
Wait until the UATI Assignment is completed.
BS Call
The mobile phone automatically responds to the
call.
RF Test
Wait until the RF test is completed.
Softer Handoff
Wait until the Softer Handoff is completed.
Connection Close
Wait until the connection is closed.
Session Close
Wait until the session is closed.
Advertising