The settings relating to the network of the recorder are configured on the setup menu - the "Advanced setup" menu - the
"Network" page.
The "Network" page has [Basic], [e-Mail], [Panasonic alarm protocol] and [NTP/SNMP] tabs.

Configure the basic network settings [Basic]

The basic settings relating to the network can be configured on this tab.

Note:

• Enter the address octets and port numbers right-aligned.[For example, for port number 80, enter 00080] The leading zeros

are omitted here.

Configure the settings relating to network [Network]

Network Setup

Configure the network settings of the recorder.

[IP address]
The IP address of the recorder will be displayed.
To change the IP address, click the [

D]/[C] button.

Default: 192.168.000.250

[Subnet mask]
Select the subnet mask in accordance with the recorder’s
network environment. Enter in the same way as the IP
address.
Default: 255.255.255.000

[Default gateway]
Select the address for the default gateway in accordance
with the recorder’s network environment. Enter in the same
way as the IP address.
Default: 192.168.000.001

[Line speed]
Specify the line speed for data transmission.

Auto: Line speed will be applied automatically.
100M-Full: 100 Mbps full-duplex
100M-Half: 100 Mbps half-duplex
10M-Full: 10 Mbps full-duplex
10M-Half: 10 Mbps half-duplex

Default: Auto

Important:

• When the setup menu is closed after changing the line

speed, the recorder will automatically restart.

DNS Setup

The settings relating to DNS (Domain Name Server) can be
configured on this tab.

[DNS]
Determine whether or not to use the DNS.

Off: Does not use the DNS.
Manual: When using DNS, it is possible to search IP

addresses by host name.

Default: Off

[Primary server address]
[Secondary server address]
When the DNS is used, select the IP addresses for the pri-
mary and secondary DNS server. Enter in the same way as
the IP address.
Default: 0.0.0.0

[Domain name]
Enter the domain name of the recorder. The first character of
the domain name should be an alphabetical character.
Enter 3 to 63 alphanumeric characters including hyphens (-)
and periods (.).
Default: localdomain