B. INSTALLATION

B.1 Pre-Installation

Uncrate the broiler and inspect for shipping damage. Remove the tape securing the machine parts, and
install the parts in their proper location. If there are obvious or concealed damages to any part of the
broiler, please contact your freight carrier. The factory warranty does not cover freight damage.

B.2 Leveling

The grease drain system is based on a gravity-flow design. Therefore, it is extremely important to level
the broiler during installation.

B.3 Hood Requirements

This appliance must be installed under a ventilation hood of adequate size and the following minimum
capacity:

Model

SCFM

N2500

1650

Do not obstruct the flow of combustion and ventilation air. An adequate air supply must be available for
safe and proper operation.

B.4 Clearance

For proper installation the minimum required clearance from combustible construction and walls is 12”
(305 mm) from all sides of the broilers. The minimum required clearance from non-combustible construc-
tion and walls is 0” (0 mm) from all sides of the broiler. Keep appliance area free from combustibles.
Check with local authorities (building and fire) for standards and requirements for wall and floor con-
struction to comply with your local codes.

B.5 Gas Connection- 1” N.P.T.

At rated input the gas supply should deliver a minimum pressure of at least 15 mbar (5" water column)
at the broiler connection for natural gas. Incoming gas supply pressure must not exceed 50 mbar (14"
water column).

REQUIRED for
installation near
combustible walls
and construction

REQUIRED for installa-
tion near non-com-
bustible walls and
construction

RECOMMENDED by
Nieco for proper disas-
sembly and service

Back of broiler

Sides of broiler

Front of broiler
(Feed end)

CAUTION

SEVERE FIRE HAZARD. Follow local fire and building codes for non-combustible construc-
tion. Failure to do so could result in a fire hazard. If unsure of your construction, follow mini-
mum clearances for combustible construction.

REQUIRED AND RECOMMENDED CLEARANCES

12” (305 mm)

12” (305 mm)

12” (305 mm)

24” (610 mm)

0” (0 mm)

0” (0 mm)

0” (0 mm)

12” (305 mm)

12” (305 mm)