C. TROUBLESHOOTING

Problem

Solution

Pilots not lighting

Check that broiler is plugged in, gas valve is
open and broiler is turned on

Manually light

Check for ignition

Check for clogged pilot

Burners not
lighting

Check for gas pressure, if there is pressure,
use the manual lighting procedure

If no gas pressure, call for service

Check for proper burner installation

Check for plugged burner orifices

Check for plugged pilot burner

Pilot not staying lit

Call for service as thermocouple may need
replacing

Broil chain jams

Check:
__ For sag in the chain (Chain may need a

link removed)

__ For an obstruction

9

Always verify that the broiler is properly assembled, the hood is on, gas valve open and broiler is plugged in.

Nieco Corporation - Model N2500

Product not cooking to
proper temperature in
cookouts

Adjust cook time

Check that broiler is calibrated properly

Check that all burners are lit

Check that all parts are installed correctly,
and that lower burner holes are facing up

Check that broiler is properly cleaned
and assembled

Check ventilation
__ Make sure there isn’t excessive

exhaust or an air vent blowing on the
broiler