Web setting screen – Vaddio HE120 Operating Instructions User Manual

Page 77

Advertising
background image

77

Web setting

Web setting screen

(continued)

Server

This screen has items that relate to the NTP server addresses, port numbers and other NTP server settings.

NTP screen

Time adjustment

<Initial setting: Off>
Select one of the following settings as the time adjustment
method.
The time is adjusted by the method selected here and
used as the unit’s standard time.

Off

The time is counted from 0:00 on
January 1, 1990 as the unit’s startup
time.

Synchronization
with NTP server

The time automatically adjusted in
synchronization with the NTP server is
used as the unit’s standard time.

NTP server address

[1 to 128 half-size characters]

<Initial setting: blank>
The host name or IP address of the NTP server is input
here.

To input the “NTP server address” host name, the
DNS setting must be selected on the Network
screen (see page 79) of the Network settings.

Note

NTP port [1 to 65535]

<Initial setting: 123>
The port number of the NTP server is input here.

Time adjustment interval

<Initial setting: 1h>
The interval (1 to 24 hours in 1-hour increments) for
acquiring the time from the NTP server and updating the
time is selected here.

Time zone

<Initial setting: (GMT) Greenwich Mean Time: Dublin,

Edinburgh, Lisbon, London>

Select the time zone that corresponds with the region in
which the unit is going to be used.

Advertising