Lack of water, Water supply – NaceCare Solutions K1122TST User Manual

Page 10

Advertising
background image

10

Please note - important:

Lack of water

Lack of water occurs more often than you

probably believe. The more powerful a

high-cleaner is the greater is the danger

that a lack of water occurs. If there is only

an insufficient amount of water available,

cavitation (water-gas mixture) arises inside

the pump, which is normally noticed too

late or even not at all.

The pump will be

destroyed!

Please check the available quantity of water

by filling a bucket with litre scale for one

minute.

If the metered quantity of water is too small, you have to use a

different water connection, guaranteeing the necessary output.

Lack of water leads to an accelerated wear of the joints

(guarantee void).

A minimum water quantity of 8.3 litres per minute (2.1 Gpm) must be available to

guarantee a trouble-free operation of the Kränzle 1122 TS T.

Water supply

Please pay attention to the regulations of your waterworks company!

In accordance with DIN EN 61770, the machine may not be directly

connected to the public drinking water supply lines. A brief connection

however is permissible according to DVGW (German Association

for Gas and Water Affairs) if a non-return valve with tube ventilator

(Kränzle order no. 41.016 4) is built into the water supply.

Once the

water has passed through the non-return valve it is no longer con-

sidered as drinking water.

Also indirect connection to the public drinking water supply lines is permissible by way
of free emission in accordance with EN 61 770; e.g. by using a reservoir with a float
valve.
Direct connection to a non-drinking water supply line is permissible.