Small repairs -

do it yourself!

The pressure gauge shows full pressure although the trigger gun with
safety catch has been closed. The pressure switch valve switches constantly.

Possible cause no.1: Leakage

Having closed th trigger gun with safety

catch, the HP cleaner must shut down and

the pressure gauge must show „0“ bar.

If the pressure gauge shows full pressure

but the motor constantly switches on and

off, a leakage at the pump, at the high-

pressure hose, at the trigger gun or at the

lance can be the reason.

Proceeding:

Check connections from the HP cleaner to

the high-pressure hose and from the hose

to the trigger gun and also the connection

between lance and trigger gun for tight-

ness.

Switch off the cleaner. Shortly press the

trigger of the trigger gun with safety catch

to decrease the pressure.

Unscrew HP hose, trigger gun with safety

catch and lance and check the O-rings.

If the O-rings are damaged they have to

be replaced.

In case of a leakage there is no guarantee for possible

consequential damages.