Range of application

Use machines for cleaning tasks with high-pressure water jet and detergents or with
high-pressure water jet without detergents only.

Inspections

The machine must be inspected according to the “Guidelines for Liquid Spray Devices”
at least once every 12 months by a qualified person, to ensure that continued safe
operation is guaranteed. The results of the inspection are to be recorded in writing. This
may be done in any form. For inspection reports see pages 44 - 45.

High-pressure cleaners used for commercial purposes have

to be checked by a qualified person at least every

12 months!

Accident prevention

The machine is designed for accidents to be impossible if used correctly. The operator is
to be notified of the risk of injury from hot machine parts and the high pressure water jet.
The “Guidelines for Liquid Spray Devices” must be complied with (see pages 36-38).

Oil change:

The first oil change should be carried out after approximately

50 operating hours. After

that no further oil change will be necessary to perform an oil change for the life cycle of
the high-pressure cleaner. If it becomes necessary during repairs, or because the oil has
a greyish colour then the oil draining screw should be opened and the oil emptied into a
container. The oil is to be caught in the reservoir and disposed of in an approved man-
ner.

New oil: 0.25 l - Motor oil: W 15/40.

Oil leakage: If oil leaks contact your nearest after-sales

service (dealer) at once. (Enviroumental damage, damage

to the transmission)

In case of increased humidity or fluctuations in

temperature development of condensed water is possible;

if the oil turns grey, it must bee changed.