Insufficient quantity of electricity, Electrical connection – NaceCare Solutions K1122TST User Manual

Page 11

Advertising
background image

11

Insufficient quantity of electricity

If there are too many collectors in your

proximity connected to the network at the

same time, the available voltage and the

current intensity may decline.

Consequently the motor of the high-pres-

sure cleaner does not start or even blows.

The power supply may also be insufficient

if the power cable is too long or too thin.

If extension cables are too long, this may lead to a voltage drop causing malfunctions or

start-up difficulties.

Check the line fusing and have the voltage and the available current

intensity checked by an expert in case of uncertainty.

Kränzle 1122 TST:

110 - 127 V ~, 14 A, 60 Hz

Electrical connection

The machine is supplied with a 5 meter electrical power cable with plug. The mains plug

must be fitted to a standard grounded socket with a

30mA residual current operated

device. The socket must be protected

with a 16A delay action fuse on the mains side.

When using an extension cable, this must have an earthed lead which is properly

connected to the socket. The conductors in the extension cable must have a minimum

cross section of

1.5 mm².

Plug connections must be of a spray-proof design, and may not be located on a wet

floor. With extension cables of

more than 10 m the minimum cross section must be

2.5 mm! When using a cable drum, always keep the cable wound as far as possible.

Advertising