Regular maintenance – NaceCare Solutions TTB516 User Manual

Page 15

Advertising
background image

233969 / 01/13 (A20)

15

Regular Maintenance

AlWAyS ENSURE tHAt tHE bAttERy IS dISCONNECtEd

PRIOR tO ANy MAINtENANCE OPERAtION

!

!

After use, empty waste-water tank using
emptying hose and flush-out with clean
water.

A

Remove the two hoses to disconnect the separator from the
machine (Fig 28).
Lift off the separator. The separator has a sealing-rubber
which should be examined at every clean-down (Fig 29).
Rinse using clean water.

NOtE:

Avoid over tightening the clean water draining cap.

The TTB 516 has been designed with ease of use in mind, this included easy stripping-down and cleaning.

Remove the two filters clipped into the separator and flush with clean water (Fig 30)(Fig 30a).
Replace by fitting the rear of the filter first then clipping the front to lock in place (Fig 31) (Fig 32).

Disconnect and remove the
battery before proceeding with
tank removal (Fig 33).

Once emptied the top
waste-water tank can simply be
lifted off. (Fig 33a).

The clean-water tank can be drained via the yellow cap fitted
to the left hand side of the machine. The cap has a rubber
seal and might require a spanner to remove. (Fig 34).

Fig 28

Fig 29

Fig 30

Fig 31

Fig 32

Fig 33

Fig 34

A

Fig 30a

Fig 33a

Advertising