Changing the floor-tool blades – NaceCare Solutions TTB516 User Manual

Page 17

Advertising
background image

233969 / 01/13 (A20)

17

Changing the Floor-tool blades

!

!

AlWAyS ENSURE tHAt tHE bAttERy IS dISCONNECtEd PRIOR tO ANy

MAINtENANCE

To change the floor-tool, firstly swing the floor-tool clear of the
machine (Fig 41).


Undo the two floor-tool retaining knobs (Fig 42).

Unscrew the four knobs securing the blade holder (Fig 43).
Remove the blade holder (Fig 44).
Replace the Squeegee blades using (606261) replacement blade set (Fig 45), fitting the blades on to the moulded
location lugs.

Refit the blade holder, retain using the two outer knobs
(Fig 46)

Refitting the Floor Tool Blades

Ensure the slotted blade goes to the front of the
floor-tool (Fig 47).

Refit the floor-tool using the two central knobs to
the floor-tool.

Refer to Page 9 for fitting instructions.

1. Floor-tool main body
2. blade carrier
3. Rear blade
4. Front blade (slotted)
5. Retaining Knobs x 4

1

2

3

5

4

Fig 41

Fig 42

Fig 43

Fig 44

Fig 45

Fig 46

Fig 47

Note:

The blades are designed to be reversible, thus

extending their useful working life.

Use Genuine NUMATIC spare parts.

use

Replacement Blade Set (606261)