NOVUS Controller N1100 User Manual

Controller n1100, Presentation, Configuration / features

Advertising
background image

NOVUS AUTOMATION

1/11

Controller N1100

UNIVERSAL CONTROLLER – INSTRUCTIONS MANUAL – V4.0x

SAFETY ALERTS

The symbols below are used on the equipment and throughout this

document to draw the user’s attention to important operational and

safety information.

CAUTION:

Read complete instructions prior to

installation and operation of the

unit.

CAUTION OR WARNING:

Electrical shock hazard.

All safety related instructions that appear in the manual must be

observed to ensure personal safety and to prevent damage to either

the instrument or the system. If the instrument is used in a manner not

specified by the manufacturer, the protection provided by the

equipment may be impaired.

PRESENTATION

The N1100 is an extraordinarily versatile process controller. It holds

in one single instrument all the main features needed for the vast

majority of industrial processes. It accepts in a single model virtually

all the sensors and signals used in the industry and provides the

main output types required for the operation of diverse processes.
The configuration can be performed directly on the controller or through

the USB interface. The NConfig software (free) is the configuration

management tool. Connected to the USB of a Windows computer, the

controller is recognized as a serial communications port (COM) running

with a Modbus RTU protocol.
Through the USB interface, even if disconnected from the power

supply, the configuration performed in a piece of equipment can be can

be saved in a file and repeated in other pieces of equipment that

require the same configuration.
It is important that the users read carefully this manual before using

the controller. Verify if the release of this manual matches the

instrument version (the firmware version is shown when the controller

is energized).
MAIN CHARACTERISTICS
• Multi-sensor universal input (sensors and standard signals);
• Protection for open sensor in any condition;
• Relay, 4-20 mA and logic pulse control outputs all available in the

standard model;

• Self-tuning of PID parameters;
• Automatic / Manual function with “bumpless” transfer;
• Four modes of independents alarms, with functions of minimum,

maximum, differential (deviation), open sensor and event;

• Timer functions that can be associated to the alarms;
• Retransmission of PV or SP in 0-20 mA or 4-20 mA;
• Input for remote setpoint;
• Digital input with 5 functions;
• Programmable soft-start;
• 7 setpoint profile programs with 7 segments each, with the ability

to be linked together for a total of 49 segments;

• Password for parameters protection;
• Universal power supply.

CONFIGURATION / FEATURES

Select the input type (in parameter “tYPE”) from Table 1 below

TYPE

CODE

CHARACTERISTICS /

RANGE OF MEASUREMENT

J

Tc j

Range: -110 to950 ºC (-166to 1742 ºF)

K

Tc k

Range: -150 to 1370 ºC (-238to 2498 ºF)

T

Tc t

Range: -160 to 400 ºC (-256to 752 ºF)

N

Tc n

Range: -270 to 1300 ºC (-454to 2372 ºF)

R

Tc r

Range: -50to 1760 ºC (-58to 3200 ºF)

S

Tc s

Range: -50to 1760 ºC (-58to 3200 ºF)

B

Tc b

Range: 400to 1800 ºC (752to 3272 ºF)

E

Tc e

Range: -90to 730ºC (-130to1346 ºF)

Pt100

Pt

Range: -200to850ºC (-328to1562ºF)

0–50 mV

L.0.50

Linear Signals
Programmable indication from-1999 to 9999

4-20 mA

L.4.20

0-5 Vdc

L0.5

4-20 mA

sqrt

4-20 mA input with Square Root extraction.
Programmable indication from-1999 to 9999

4-20 mA

NON

LINEAR

ln j

Non Linear Analog Signals
Indication range depends on the selected sensor

Ln k

ln t

ln n

ln r

ln s

ln b

ln E

Ln.Pt

Table 1 – Input types

Note: All input types are factory calibrated.

OUTPUTS, ALARMS AND DIGITAL INPUTS CONFIGURATION
The controller input and output channels (I / O) can assume multiple

functions: control output, digital input, digital output, alarm output,

retransmission of PV and SP. These channels are identified as I / O

1, I / O 2, I / O 3, I / O 4 and I / O 5.
The basic controller model comes loaded with the following features:

I / O 1- output to Relay SPST-NA;

I / O 2- output to Relay SPST-NA;

I / O 5- current output, digital output, digital input;

Optionally, other features can be added, as shown under the item

“Identification” in this manual:

- 3R: I / O3 with output to SPDT relay;
- DIO: I / O3 and I / O4 as digital input and output channels;
- 485: Serial Communication