Commissioning, Startup, Operation, and Shutdown
Stage length
Pump size
Temperature threshold for hot
doweling
8
3x4-8
N/A
3x4-9
360°F (182°C)
3x6-9/10
380°F (193°C)
4x6-10
330°F (166°C)
4x6-10D
310°F (154°C)
4x6-11
4x6-11D
280°F (138°C)
6x8-11
6x8-11D
250°F (121°C)
6x8-13
6x8-14
230°F (110°C)
9
3x4-8
370°F (188°C)
3x4-9
340°F (171°C)
3x6-9/10
360°F (182°C)
3x4-12.5
290°F (143°C)
4x6-12
4x6-10
4x6-10D
4x6-11
4x6-11D
260°F (127°C)
6x8-11
6x8-11D
240°F (116°C)
10
3x4-8
350°F (177°C)
3x4-9
310°F (154°C)
3x6-9/10
330°F (166°C)
3x4-12.5
270°F (132°C)
4x6-12
4x6-10
4x6-10D
4x6-11
4x6-11D
250°F (121°C)
6x8-11
6x8-11D
220°F (104°C)
11
3x4-8
330°F (166°C)
3x4-9
300°F (149°C)
3x6-9/10
4x6-10
270°F (132°C)
3x4-12.5
250°F (121°C)
4x6-12
4x6-10D
4x6-11
4x6-11D
240°F (116°C)
12
3x4-8
310°F (154°C)
3x4-9
280°F (138°C)
3x6-9/10
3x4-12.5
240°F (116°C)
4x6-12
4x6-10
4x6-10D
4x6-11
4x6-11D
220°F (104°C)
13
3x4-8
290°F (143°C)
3x4-9
260°F (127°C)
3x6-9/10
3x4-12.5
220°F (104°C)
4x6-12
Model 3600, API 610 8th, 9th, 10th & 11th Editions (ISO 13709) Installation, Operation, and Maintenance Manual