Maintenance

2. Measure the depth of the ring bores noted in the figure and record the measurements in the

table row "Actual depth."

1. Inboard seal chamber
2. Last ring bore
3. First ring, inboard side
4. Inboard center bushing bore
5. Outboard center bushing bore
6. Last ring, outboard side
7. First ring bore
8. Outboard seal chamber

A. Lower half casing flange
B. Inboard end
C. Outboard end

Location

1

2

3

4

5

6

7

8

Design depth
Actual depth
Difference

Design depth in inches

Pump size

1 and 8

7

2 through 6

3x4-8B

3.139

3.115

3.115

3x4-9

3.145

3.145

3.145

3x6-9/10

3.139

3.615

3.115

3x4-12.5

3.145

3.370

3.370

4x6-12

3.145

3.370

3.370

4x6-10

3.139

3.584

3.302

4x6-10D

3.139

3.302

3.302

4x6-11

3.139

3.552

3.990

4x6-11D

3.139

3.990

3.990

4x6-11A

3.145

3.995

3.995

6x8-11

3.145

4.427

4.427

6x8-13

3.745

4.745

4.745

6x8-14

3.145

4.620

4.620

8x10-13

3.145

4.870

4.870

10x12-14.5

3.342

5.275

5.275

3. For each bore, subtract the actual depth from the design depth and record the difference in

the table.