Warning – Goulds Pumps AF (Axial Flow) (6"-36) MXR Bearings" User Manual
Page 25

AF (6-36) IOM
23
The general method of tensioning belts is given
below, and should satisfy most drive requirements.
General Method:
STEP 1. Reduce the center distance so that the belts
may be placed over the sheaves and in the grooves
without forcing them over the sides of the grooves.
Arrange the belts so that both belt spans have a
proximately the same sag between the sheaves.
Apply tension to the belts by increasing the center
distance until the belts are snug, see Fig. 18.
WARNING
Do not operate the pump without the proper drive
guard in place. Failure to observe this warning
could result in personal injury to operating
personnel
STEP 2. Operate the drive a few minutes to seat the
belts in the sheave grooves. Observe the operation
of the drive under its highest load condition (usually
starting). A Slight bowing of the slack side of the
drive indicates proper tension. If the slack side
remains taut during the peak load, the drive is too
tight. Excessive bowing or slippage indicates
insufficient tension. If the belts squeal as the motor
begins operation or at some subsequent peak load,
they are not tight enough to deliver the torque
demanded by the drive machine. The drive should be
stopped and the belts tightened.
STEP 3. Check the tension on a new drive frequently
during the first day by observing the slack side span.
After a few days of operation the belts will seat
themselves in the sheave grooves and it may become
necessary to readjust so that the drive again shows a
slight bow in the slack side.
Other methods of determining proper belt tension can
be obtained from the drive manufacturer.
5. Use Belt Guards - Belt guards protect personnel
from danger and the drive from contamination.
Inspect periodically to assure that belts do not rub
against guard.
6. Keep Belts Clean - Dirt and grease reduce belt
life. An occasional wiping with a dry cloth to
remove any build-up of a foreign material can
extend the life of the belt. Should oil or grease
splatter onto the belts, clean with soap and water.
Belt dressing affects performance only temporarily and
is never recommended. Maintaining a clean drive is a
better practice.
If any questions arise pertaining to the drive limitations,
consult the manufacturer.
GEAR DRIVE (COUPLINGS)
The coupling used in an ATEX classified
environment must be properly certified.
Remove the guard or guards by referring to the
assembly/disassembly instructions. Disconnect
motor/gearbox and the pump/gearbox coupling halves
before proceeding with the alignment. First, align the
pump/gearbox coupling then the motor/gearbox
coupling. Check both coupling connections for parallel
and angular alignment by either the Dial Indicator or
Straight-Edge Method outlined below.
Fig. 18
Fig. 19
3
!