Disassembly & re-assembly, Required tools, Disassembly – Goulds Pumps AF (Axial Flow) (6"-36) MXR Bearings" User Manual

Page 47: Warning

Advertising
background image

AF (6-36) IOM

45


DISASSEMBLY & RE-ASSEMBLY

REQUIRED TOOLS ....................................................................................... 45
DISASSEMBLY
............................................................................................. 45
INSPECTIONS
.............................................................................................. 52
RE-ASSEMBLY
............................................................................................. 55

PARTS LIST & SECTIONAL DRAWINGS ............................................... 62-66

REQUIRED TOOLS

Safety glasses, leather gloves

11/16”, 7/8”, 1-1/16”, 1-1/4”, 1-5/8” wrenches or

sockets

Lifting slings or chains

Induction bearing heater

Brass drift punch

Spanner wrench

Allen wrenches

Torque wrench with sockets

Micrometer

Cleaning Agents

Feeler gauges

Bearing puller

Crane or hoist

Lifting eyebolt (dependent on pump size)

DISASSEMBLY

Disassembly procedures were written assuming the
entire pump and sub-base have been removed from the
piping. In most cases only the back pullout will need to
be removed for maintenance, the elbow can remain in
the piping.

WARNING

Pump components can be heavy. Proper methods
of lifting must be employed to avoid physical injury
and or equipment damage.

WARNING

The AF may handle hazardous and/or toxic fluids.
Skin and eye protection is required. Precautions
must be taken to prevent physical injury. Pumpage
must be handled and disposed of in conformance
with applicable Environmental Regulations.


NOTE: Before disassembling the pump for overhaul,
ensure all replacement parts are available.

WARNING

Lock out driver power to prevent accidental start-up
and physical injury.

1. Shut all valves controlling flow “to and from” the

pump.

WARNING

Operator must be aware of pumpage and safety
precautions to prevent physical injury.

2. Drain liquid from piping, flush the pump if necessary.

3. Disconnect all auxiliary piping and tubing.

6

!

!

!

!

Advertising