Goulds Pumps AF (Axial Flow) (6"-36) MXR Bearings" User Manual

Page 60

Advertising
background image

58

AF (6-36) IOM


Mechanical Seal w/ Optional Adapter

16. The loose mechanical seal (383, 108) components

and gaskets (211) are slid onto the shaft (122) first
before the stuffing box cover (184) can be
installed. If the seal includes a restrictor bushing
(496B) an optional adapter (108B) will be included
with the pump. On large pumps use a sling or
hook and chain to securely support the weight of
the stuffing box cover during installation. Mount
the stuffing box cover on the bearing housing
(134C) register. Secure the stuffing box cover
(184) to the bearing housing (134C) using two
bolts (370C). Be careful not to scuff or mar the
pump shaft (122) during installation. Install the
four adjusting lugs (415) and impeller adjusting
bolts (356A). Use the upper adjusting screws
(356A) closest to the bearing housing to center the
stuffing box cover on the shaft. The seal
manufacturers instructions should be followed to
correctly install and align the mechanical seal.
Lastly, install the seal gland nuts (353) and secure
the seal to the stuffing box cover (184). Be sure
all gland quench or flush tubing is connected. see.
Fig. 64.

IMPELLER


Standard Impeller

17. Install the shaft key (178). Slide the impeller (101)

onto the shaft (122) and if necessary use a
wooden mallet to set it in place against the shaft
shoulder. Install the shaft washer (199) and
fasteners (198), tighten to lock the impeller (101)
in place, see Fig. 65.

Sealed Impeller

18. 700mm and 36” sizes use an impeller cover and

O-rings to keep pumpage out of the impeller
cavity. First, install the shaft key (178) on the
shaft. Using some silicone stick the impeller O-ring
(412A) to the back side of the impeller (101).
Slide the impeller (101) onto the shaft (122). If
necessary use a wooden mallet to set it in place
against the shaft shoulder. Install the shaft
washer (199) and bolts (198). Place the O-ring
(412T) on the cover and fasten the cover (998E) to
the impeller (101) using bolts (370M). Some
impeller covers have a pipe test plug (408H)
located on the face of the cover to test the cavity
seal after re-assembly, Re-install this plug (358I),
see Fig. 66.

Fig. 63

412D

122

220

370C

126

134C

351W

799E

105

106

184

356A

469D

178D

107

353

415

Fig. 64

370C

122

383

108B

415

134C

353

496B

211

356A

184

355

Fig. 65

101

178

122

199

198

Fig. 66

122

412A

101

198

358I

370M

998E

412T

199

178