AF (6-36) IOM

61

this time. Install the pump to sub-base bolts
(500A) and remove the lifting straps or chains from
around the bearing housing (134) and elbow
(100), see Fig. 74.


26. Align the gear box and pump coupling halves as

described on pg.’s 20 ~ 23 of section 3. If the
motor and gear box were moved during
disassembly re-align they must be re-aligned also.


27. Wrap the coupling cover around the coupling

halves and install the fasteners that hold the
coupling cover together, see Fig. 75.

28. Bolt the two halves of the coupling guard (500)

together and install over the coupling. Fasten the
guard to the sub-base using screws (502), see
Fig. 76.


29. Check impeller alignment and re-align if necessary

according to instructions on pg. 28 of section 3.


30. Fill pump with proper lubricant. Refer to

preventative maintenance for requirements.


31. Connect all auxiliary piping and tubing.

32. Fill system piping so pump impeller is submerged,

flush the pump if necessary.


33. Open all valves controlling flow “to and from” the

pump.


34. Un-lock driver power and jog the pump motor to

be sure the pump rotates with no binding or rubs.
If all is proper, continue with pump start-up.

WARNING

With power unlocked be careful so as to prevent
accidental start-up and physical injury.

WARNING

Operator should be aware of pumpage and safety
precautions to prevent physical injury.

Fig. 74

500A

500A

100

134

Fig. 75

COUPLING

COVER

Fig. 76

500

502