background image

1

2

3

4

5

6

7

Figure 5: Location of the float, rod, and switch

1. Diameter of the coverplate (A)
2. Radius (B)
3. CL of the pump
4. Radius of 7.0 in. (178.0 mm)
5. 1.25 in. (31.8 mm) NPT float switch NTG

column

6. 0.38 in. (9.5 mm) NPT for the float rod guide
7. 8 in. (203.0 mm) diameter of float (standard)

Number

Coverplate diameter (A)

Radius (B)

1

22 in. (559 mm)

14.50 in. (368 mm)

2

26.50 in. (673 mm)

16.50 in. (419 mm)

3

31.00 in. (787 mm)

18.50 in. (470 mm)

1. Before you install the pump in the sump, attach the lower guide arm (366) and the float rod guide

(336) to the correct suction cover bolt (based on the layout).

2. Thread the float switch support pipe (435) and the upper rod guide (337) into the pit cover.
3. Attach the float switch bracket (398) to the float switch support pipe.

You can rotate the float switch around the center line of the pump on the radius (B).

4. Install the float rod (334), float (342), and collars (335).

You must maintain the radius (4) between the float switch column and the float.

339

435

335

398

337

437

335

342

335

334

336

366

Installation