501L

338

371L 240

501

2. Place the sling on the motor lifting lugs and remove the motor.
3. Remove the support plate anchor bolts.
4. Attach the eyebolts to the support plate.
5. Use properly-sized slings in order to lift the pump from the sump.

Refer to the Installation chapter for the proper handling procedure.

6. Lay the pump horizontally on proper supports where there is sufficient clearance to disassemble the

pump.

7. Remove the bolts (317N) in order to remove the strainer (187).

351A

370H

182

187

317N

351

8. Remove the suction cover (182).
9. Remove and discard the suction cover gasket (351).

Replace the gasket during reassembly.

10. Remove the discharge elbow-casing bolts (370H).
11. Disconnect any steady bearing flush tubing (190).