Goulds Pumps CV 3171 - IOM User Manual

Page 42

Advertising
background image


42

CV 3171 IOM 05/11

 

NOTE: There are several methods for installing
bearings. The recommended method is to use
an induction heater that heats as well as
demagnetizes the bearing.

WARNING

Use insulated gloves when using a
bearing heater. Bearings will get hot
and can cause physical injury.


3. Install lockwasher (382) on shaft (122). Place

tang of lockwasher in keyway of shaft.


4. Thread locknut (136) onto shaft (122). Tighten

locknut until snug. Bend any tang of the
lockwasher into one of the slots on the locknut.
Tighten the locknut if necessary to align
lockwasher tab with a locknut slot.


5. Press grease seal (333) into bearing shell (134).

The seal is mounted with the lip out, facing
toward the pump casing.


6. Slide bearing shell onto pump end of shaft and

over the bearing.


7. Insert retaining ring (361A) in bearing shell

groove keeping flat side against bearing.


8. Slide labyrinth seal (332A) over coupling end of

shaft. Press into bearing shell unit to shoulder.


9. With the support plate in a vertical position,

slide the shaft horizontally through the motor
support. Support the shaft and column with
suitable stands (Figure 35).

10. Install hold down bolts (370C) and jacking bolts

(370D) with jam nuts (415).

ASSEMBLY

OF

COLUMN

(WHEN

REQUIRED)

When intermediate steady bearings are required,
there will be additional column extensions (306) and
steady bearing housings (213) required.

1. Prepare

the

steady

bearing

housing

assembly(s) if required. Press in new steady
bearing. Install snap ring and seals on sealed
bearings (Figure 31). The seals are mounted
with the lips out, facing away from the steady
bearing.

NOTE: The steady bearing does not have to be
centered exactly nor do the holes in the bearing
have to line up with the holes in the housing.
There is a recessed area on the inside of the
housing (213) that allow lubricants to find the
opening in the bearing.

2. Slide steady bearing housing assembly (213)

onto the shaft. Seat housing against flange of
column pipe. Make sure that the drilled flush tap
matches the location of the holes in the support
plate.

3. Install column extension (306). Make sure

match marks scribed during disassembly line
up. Install bolts (372B).

4. Repeat steps 1-4 as necessary.

Figure 35 

Figure 34 

Advertising