Goulds Pumps CV 3171 - IOM User Manual

Page 44

Advertising
background image


44

CV 3171 IOM 05/11

 

8. Install upper pipe nut (242). Tighten pipe nuts

against support plate. Make sure that the pipe
nuts are tight and that no strain has been
placed on the pump. Rotate shaft by hand to
assure there is no binding

9. Install strainer (187) with bolts (Figure 40).

10. Connect all auxiliary piping.

11. Replace the pump half-coupling hub (233).

12. Install motor and attach coupling (Figure 41).

13. Adjust impeller clearance following the impeller

clearance setting procedure (Section 5).

14. Install coupling guard (501) (Figure 42).

15. Lubricate the pump bearings.

16. Follow directions in Section 3 and 4 for

installation and operation.

Figure 39 

Figure 42 

Figure 40 

Figure 41 

Advertising