Install a solid-shaft driver – Goulds Pumps VIC - IOM User Manual
Page 36
1
2
3
1.
Connection to external seal lubrication
2.
Bypass to suction
3.
Connection to external seal lubrication
Figure 7: Tandem-mounted seal (dual unpressurized)
1
2
1.
Bypass to suction
2.
Connection to external seal lubrication
Figure 8: Double-mounted seal (dual pressurized)
Install a solid-shaft driver
WARNING:
• When installing in a potentially explosive environment, make sure that the motor is properly certified.
• Do not test the motor for direction of rotation when it is coupled to the pump. If the pump rotates in
the wrong direction, serious damage to the pump, motor, and personnel will result.
• Do not work under a heavy and suspended object unless there is a positive support and safeguards
that will protect you if a hoist or sling fails.
Installation (Continued)
34
Model VIC Installation, Operation, and Maintenance