NOTICE:

• When the pump is supplied with a thrust pot, do not secure the driver to the discharge head until after

the thrust pot and flexible coupling are installed. A separate supplement for thrust pots will be
furnished as required.

• Read and follow the motor manufacturer's instructions before lubricating the motor bearings.

Excessive lubrication can cause the bearings to overheat and fail prematurely.

The coupling between the driveshaft and the discharge-head shaft can either be a non-spacer type or a
spacer type. The spacer type is used on pumps furnished with a mechanical seal to permit servicing of the
seal without the removal of the driver.

1

2

3

4

5

6

7

8

9

10

1.

Driveshaft

2.

Driver key, supplied by motor vendor

3.

Driver hub

4.

Adjusting plate

5.

Pump hub

6.

Pump key

7.

Headshaft

8.

Hex nut

9.

Capscrew

10. Split ring

Figure 9: Non-spacer type coupling