Runout of

driver shaft

Procedure

Flatness of the

seal housing

For this measurement, remove the mechanical seal if the dial indicator stylus cannot

rotate 360° on the top surface of the seal gland.
1. Remove the lower coupling components and attach the base of the dial indicator

to the driver shaft.

2. Place the stylus at the top surface of the seal gland, or at the top surface of the

seal housing.

3. Rotate the driver shaft slowly 360°.
4. Check that the face of the seal housing is square with the shaft to within 0.002 in.

(0.05 mm) TIR.