Install the tube tension plate – Goulds Pumps VIT - IOM User Manual

Page 38

Advertising
background image

c) Tighten the nuts or bolts just enough to seal at the gland ring gasket.

1

2

3

1.

Connection to external seal lubrication

2.

Bypass to suction

3.

Connection to external seal lubrication

Figure 7: Tandem-mounted seal (dual unpressurized)

1

2

1.

Bypass to suction

2.

Connection to external seal lubrication

Figure 8: Double-mounted seal (dual pressurized)

Install the tube tension plate

1. Lubricate the tube threads and the underside of the tension-plate flange with a thread compound.
2. Thread the tension plate onto the enclosing tube nipple manually until its shoulder rests on the

discharge head.

Installation (Continued)

36

Model VIT Installation, Operation, and Maintenance