Install the tube tension plate – Goulds Pumps VIT - IOM User Manual
Page 38
Advertising
c) Tighten the nuts or bolts just enough to seal at the gland ring gasket.
1
2
3
1.
Connection to external seal lubrication
2.
Bypass to suction
3.
Connection to external seal lubrication
Figure 7: Tandem-mounted seal (dual unpressurized)
1
2
1.
Bypass to suction
2.
Connection to external seal lubrication
Figure 8: Double-mounted seal (dual pressurized)
Install the tube tension plate
1. Lubricate the tube threads and the underside of the tension-plate flange with a thread compound.
2. Thread the tension plate onto the enclosing tube nipple manually until its shoulder rests on the
discharge head.
Installation (Continued)
36
Model VIT Installation, Operation, and Maintenance