Runout of

driver shaft

Procedure

Concentricity

of the seal

housing

This measurement requires that you remove the mechanical seal.
1. Install the dial indicator as shown.
2. Rotate the driver shaft by hand and run the indicator in the inside-machined

surface of the seal housing to determine the concentricity.

3. If the indicator reads higher than 0.004 in. (0.10 mm) TIR, loosen the four driver

hold-down bolts and relocate the driver on the motor base register.

4. Obtain the desired position.
5. Tighten the hold-down bolts and repeat the indicator reading.