11. Remove Drain Plugs allowing tanks to drain.

12. Adjust Detergent and Sanitizer Pumps. (See pages 9-10)

13. Replace Drain Plugs.

14. Turn Fill Switch to “on” position. The Wash and Rinse Tanks should now fill near the top of the

overflow walls. When the Wash Tank is full, the thermostatically controlled Heater will turn on and

off as necessary to maintain the water temperature at approximately 150° F.

NOTE: The Thermostat is preset at the factory.

15. Install Rinse Tank Guide (see Figure 2, page 4 - item 9).

16. Install Wash, Rinse, and Front Curtains (see Figure 1, page 3 - items 4, 5, and 6).

17. The unit is now ready to test detergent and sanitizer strength. Your chemical supplier will test the

concentration levels which are:

a. .30% for detergent, and

b. 50 PPM (parts per million) for chlorine bleach sanitizer, or

c. 12.5 PPM for iodine sanitizer.

Turn Conveyor Switch to “on” position for approximately 30 seconds to mix water and chemicals for

testing purposes. If further adjustment is necessary, refer to the next section on Peristaltic Pump Adjustment.

18. This glasswasher is equipped with an Empty Sensor for the Detergent and Sanitizer. Check the

operation by lifting the Detergent Feed Line from the Detergent container. This should turn on the visual

alarm. Place Detergent Feed Line back into Detergent container and repeat procedure for Sanitizer Feed Line.

19. Install Conveyor (see Figure 1, page 3 - item 3) and Front Shield (see Figure 1, page 3 - item 7). The Front

Shield clips to the Top Section.

20. Install front panel of Main Section (see Figure 1, page 3).

21. Your glasswasher is now ready for operation.

s

TarT

-u

p

I

nsTrucTIons

p

erIsTalTIc

p

ump

a

dJusTmenT

u

nITs

m

anuFacTured

b

eFore

J

anuary

2003 - d

IsconTInued

c

IrcuIT

b

oard

T

ype

1. Locate Peristaltic Pump in Glasswasher.

2. Locate Pump Control Circuit Board.

3. Each pump has its own adjustment dial.

One for Detergent and one for Sanitizer.

Turn dial clockwise for faster pump speed

or counter-clockwise for slower pump

speed.