Roubleshooting, Uide – Glastender GT-30 User Manual

Page 23

Advertising
background image

Glastender, Inc. • 5400 North Michigan Road • Saginaw, MI • 48604-9780

800.748.0423 • 989.752.4275 • Fax 989.752.4444 • www.glastender.com

21

T

roubleshooTInG

G

uIde

T

rouble

or

s

ITuaTIon

c

ause

r

emedy

O. Cold water runs contin-

1. Liquid level out of adjustment.

1. Remove obstruction or readjust.

uously, and sanitizer

2. Defective liquid level switch.

2. Test switch and replace if

pump is functioning

necessary.

P. Cold water runs contin-

1. Cold water inlet valve

1. Clean or replace cold water

uously, but sanitizer

not seating properly.

inlet valve.

pump turns on and off

Q. Heater glowing

1. Wash tank water valve

1. Replace valve.

not opening.

2. Liquid level switch stuck

2. Replace switch.

in closed position.

R. Detergent and/or

1. Detergent and/or sanitizer

1. Refill or replace container(s).

sanitizer not feeding

container(s) are empty.

properly

2. Feed lines will not fill.

2. Replace defective parts.

Notes: The detergent or sanitizer

product advances in the line on

each stroke of the pump. The

product should hold position

between strokes. If the product

falls back toward the supply

container, one or more of the fol-

lowing conditions may exist:

a. Debris in pump,

b. Split feed line, or

c. Bad pump tube.

Replace parts as necessary.

S. Poor washing results

1. Clogged spray nozzles and

1. Clean unit. See cleaning

dirty wash tank.

instructions, pg. 17-18.

2. Detergent container empty.

2. Fill container.

3. Poor water conditions.

3. Have filter or softener installed.

4. Chemicals not adjusted

4. Call chemical technician.

properly.

5.

Curtains not installed properly.

5. Install curtains properly.

T. Glasses are “sudsy”

1. Iodine-type sanitizer used.

1a. Re-adjust iodine solution.

1b. Replace with chlorine bleach

(sodium hypochlorite - 5.25%

solution).

Advertising
This manual is related to the following products: