ADTRAN Cable T1 ESF CSU ACE User Manual

Page 43

Advertising
background image

Chapter 4. Operation

61202066L1-1B

T1 ESF CSU Rackmount User Manual

43

Figure 4-14. DATAMATE Status Menu Tree

(*YES, -NO)

NI RXAIS *

Figure 4-15. DATAMATE Status Display Example

Performance Monitoring statistics for either the local or the remote Tl ESF
CSU RM can be viewed on the DATAMATE or displayed on a CRT
screen via the terminal interface for the SMART 16 shelf.

The parameters available in the performance monitoring reports are:

%AV

percent available seconds

%EF

percent error-free seconds

ES

errored seconds

UAS unavailable

seconds

SES

severely errored seconds

BES

Bursty errored seconds

LOFC

loss of frame count.

1 = CLEAR HISTORY

2 = CURR/ALM

1 = STATUS

3 = ERR/ALM HIST

4 = RESET LOC PERF

5 = VIEW LOC PERF

In the status displays above, NI means network interface
and TI means terminal or DTE interface. In the DATA-
MATE status display example above, the first line indicates
that an asterisk (*) means Yes and a dash (-) means No. The
second line lists the applicable interface alarm in question.
The last field is the state of the error/alarm.