Refrigerant line set installation, A-vfh outdoor liquid-gas connection sizes, B-vfh indoor liquid-gas connection sizes – Comfort-Aire A-VFH42PA-1 User Manual

Page 13

Advertising
background image

13

Heat Controller

VFH InverterFlex

®

- Outdoor Ductless Mini-Split

Due to the mix and match nature of the InverterFlex™ system, reducing and/or
expansion flare connection subassemblies are provided with some models to

accommodate for the different flare connections sizes between indoor and outdoor

units.

The subassemblies provided accommodate for most typical applications, however
the installing contractor may need to purchase additional subassemblies for certain

applications.

A-VFH Outdoor Liquid-Gas Connection Sizes

B-VFH Indoor Liquid-Gas Connection Sizes

Subassemblies for

A-VFH36QA-1 and A-

VFH42PA-1 Outdoor

Units:

The A-VFH36QA-1 and A-VFH42PA-1 outdoor units come with a set of copper elbow subassemblies with a female flare
nut x male flare fitting.

Liquid Connections

18K

24K

30K

36K

42K

A

1/4” (6.35mm)

1/4” (6.35mm)

1/4” (6.35mm)

1/4” (6.35mm)

1/4” (6.35mm)

B

1/4” (6.35mm)

1/4” (6.35mm)

1/4” (6.35mm)

1/4” (6.35mm)

1/4” (6.35mm)

C

n/a

1/4” (6.35mm)

1/4” (6.35mm)

1/4” (6.35mm)

1/4” (6.35mm)

D

n/a

n/a

1/4” (6.35mm)

3/8” (9.52mm)

1/4” (6.35mm)

E

n/a

n/a

n/a

n/a

3/8” (9.52mm)

Gas Connections

18K

24K

30K

36K

42K

A

3/8” (9.52mm)

3/8” (9.52mm)

3/8” (9.52mm)

3/8” (9.52mm)

3/8” (9.52mm)

B

3/8” (9.52mm)

3/8” (9.52mm)

3/8” (9.52mm)

3/8” (9.52mm)

3/8” (9.52mm)

C

n/a

3/8” (9.52mm)

3/8” (9.52mm)

1/2” (12.7mm)

1/2” (12.7mm)

D

n/a

n/a

3/8” (9.52mm)

5/8” (15.9mm)

1/2” (12.7mm)

E

n/a

n/a

n/a

n/a

5/8” (15.9mm)

Indoor Unit

Liquid

Gas

B-VFH09MA-1

1/4” (6.35mm)

1/2” (12.7mm)

B-VFH12MA-1
B-VFH18MA-1

5/8” (15.9mm)

B-VFH12CA-1

3/8” (9.52mm)

B-VFH18CA-1

1/2” (12.7mm)

B-VFH24CA-1

3/8” (9.52mm) 5/8” (15.9mm)

Refrigerant Line Set Installation

Advertising
This manual is related to the following products: