VFH InverterFlex

®

- Outdoor Ductless Mini-Split

Heat Controller

Electrical Work

Outdoor unit power and

communication cable wiring

1. Remove the electrical control cover from the

outdoor unit (Fig. 13).

2. Connect power supply wires to the outdoor unit’s

terminal strip (Fig. 14-19).

3. Connect the communication cable from the

indoor unit to the outdoor unit’s terminal strip on

the left side. Repeat for each indoor unit (Fig.

14-19).

4. Connect the ground wire of the communication

cable to the ground terminal (Fig. 14-19).

5. To prevent water from entering in the unit, form a

loop in the cable (Fig. 13).

6. Insulate any unused conductors with electrical

tape, so that they do not touch any other

exposed electrical or metal parts.

7. Replace the electrical control cover that was

removed in Step 1.

Fig. 13

Cover

Screw

Loop the

cable

Air inlet (rear)

Air outlet

Air inlet (side)

1. The power cable should be placed in the hole

under connection cable cover.

2. If connecting two indoor units, the connection cable

should be placed in hole A and hole B.

3. If connecting three indoor units, the connection

cable should be placed in hole A, B and C.

4. If connecting four indoor unit, the connection cable

should be placed in hole A, B, C and D.

5. If connecting five indoor units, the connecting

cables should be places in holes A, B, C, D and E.