Heat Controller

VFH InverterFlex

®

- Outdoor Ductless Mini-Split

WARNING!

!

CAUTION!

!

This symbol indicates the possibility of death or serious injury.

This symbol indicates the possibility of injury or damage to property.

This symbol denotes procedure that is PROHIBITED.

The items to be followed are classified by the symbols:

1)

Do not install without an authorized servicer/installer.

2)

Install according to this installation instruction. If installation is defective, it can cause water leakage or

electrical shock/fire.

3)

Use the supplied accessories and specified parts for installation.

4)

Install the outdoor unit on a raised concrete pad or blocks to provide a solid, level foundation. In a

location with high winds, anchor the unit and provide an air baffle. In snowy areas (for heat pump

models), install the outdoor unit on a raised platform higher than drifting snow. Provide snow vents, and

awning over the unit.

5)

For electrical work, follow local and national electric codes and these installation instructions. An

independent must be used. If defects in the electrical work, will cause electrical shock or fire.

6)

Use the specified cable and connect tightly. Clamp the cable so that no external force will stress the

connections. Loose wiring may overheat at the connection points and create a possible fire hazard.

7)

Wiring routing must be properly arranged so that control board cover is fixed properly. If control board

cover is not fixed perfectly, it will cause overheating at connection point of terminal, fire or electrical shock.

8)

When charging the unit, take care not to let air/substances other than the specified refrigerant

go into refrigeration circuit. Otherwise, it will cause lower capacity, abnormal high pressure in the

refrigeration circuit, explosion and injury.

9)

Do not modify the length of the power supply cord or use an extension cord, and do not share

the single outlet with other electrical appliances. Otherwise, it will cause fire or electrical shock.

1)

This equipment must be grounded. It may cause electrical shock if grounding doesn’t comply with local/

national electric codes.

2)

Do not install the unit in a place where leakage of flammable gas may occur. If gas leaks and

accumulates near the unit, it may cause fire.

3)

Provide proper condensate drainage per the installation instructions. If not done properly, condensate

can destroy personal property and freeze up in improperly on the unit.

WARNING!

!

CAUTION!

!

• Read the follow SAFETY PRECAUTIONS carefully before installation.

• Electrical work must be performed by a licensed electrician. Be sure to use the correct rating of the power

cord and main circuit for the model to be installed.

• Incorrect installation due to ignoring the instruction will cause harm or damage.

n