SawStop Sliding Crosscut Table User Manual

Page 12

Advertising
background image

SawStop TSA-SA48 Sliding Crosscut Table | 8

6. Pull out the sliding table lock knob on the underside of the sliding table assembly and rotate it 90 degrees to

unlock the sliding table. Then slide the table top toward the front of the saw to expose two of the mounting
holes, as shown in

Fig. 8.

Fig. 8

(ICS Model Shown)

7. For ICS saws ONLY: With the mounting holes aligned, thread two M10x1.5x25 cap screws (121) with two

10mm lock washers (122) and two 10mm flat washers (123) through the sliding table into the saw table.
Only finger tighten the cap screws at this time. Position the flat edge on the flat washers facing downward.

8. For PCS and CNS saws ONLY: With the mounting holes aligned, thread two M8x1.25x25 cap screws (106)

with two 8mm lock washers (107) and two 8mm flat washers (108) through the sliding table into the
mounting holes of the saw table. Only finger tighten the cap screws at this time.

9. Slide the table top toward the back of the saw to expose the final mounting hole(s) and install the remaining

cap screw(s), lock washer(s), and flat washer(s). Only finger tighten the cap screws at this time.

10. Slide the table top as necessary until only one cap screw is exposed at the front of the saw. Lay a straight

edge across the sliding table top so that it extends over the top of the table saw as close to the exposed cap
screw as possible. Make sure the sliding table top is parallel to the top of the saw table and then adjust the
foot pad on the bottom of the front leg until the sliding table top is between 0.010" and 0.020" higher than the
table saw top. Tighten the exposed cap screw. Slide the table toward the front of the saw to expose one cap
screw at the back of the saw and repeat the process at this location. Recheck both ends of the table (front
and back) to make sure they are still correct. Then tighten the remaining fasteners.

11. Pull out the sliding table lock knob on the underside of the sliding table assembly, rotate it 90 degrees then

release. Slide the table top toward the Home Position until it locks in place.

Advertising