Specifications – WIKA TSD-30 User Manual

Page 12

Advertising
background image

12

WIKA operating instructions temperature switch model TSD-30

GB

11613025.02 12/2011 GB/D/F/E

3. Specifications

3.7 Operating conditions
Temperatures and humidity
Medium temperature: -20 ... +80 °C

Ambient temperature: -20 ... +80 °C

Storage temperature: -20 ... +80 °C

Permissible humidity: 45 ... 75 % relative

Installation instructions

Mounting position: as required

At high medium or ambient temperatures, ensure by suitable measures that the instrument case temper-

ature does not exceed 80 °C in continuous operation (the temperature is measured at the hexagon of

the process connection).

At temperatures above 80 °C the thread must not be immersed into the medium.

3.8 Materials
Wetted parts

Temperature sensor: Stainless steel 316Ti
Non-wetted parts

Case:

Stainless steel 304

Keyboard

TPE-E

Display window: PC

Display head:

PC + ABS-Blend

3.9 Approvals, directives and certificates
CE conformity

EMC directive:

2004/108/EC, EN 61326-2-3 emission (group 1, class B)

and interference immunity (industrial application)

RoHS conformity: Yes

Advertising